Avantgarde.Line | BF Series Forced convection
Request additional information
Full description
Temperature range (model 56 | 260): ambient temperature plus 7 °C to 100 °C
Temperature range (model 115): ambient temperature plus 8 °C to 100 °C
High temperature accuracy thanks to APT.line™ technology
Forced convection
Controller with LCD display
Electromechanical control of the exhaust air flap
Inner door made of tempered safety glass
2 chrome-plated racks
Units up to 115 L are stackable
Class 3.1 integrated independent temperature safety device (DIN 12880) with visual alarm
Ergonomic handle design
USB port for recording data
Product specification
Model
BF 56
BF 115
BF 260
BF 720
Measures
Interior volume [L]
59
114
257
734
Net weight of the unit (empty) [kg]
38
54
85
166
Permitted load [kg]
70
150
270
315
Load per rack [kg]
30
30
40
45
Internal Dimensions
Width [mm]
400
550
650
1000
Height [mm]
440
550
780
1300
Depth [mm]
340
380
510
565
Doors
Unit doors
1
1
1
2
Inner doors
-
-
-
2
Outer dimensions
Width net [mm]
560
710
810
1165
Height net [mm]
625
735
965
1590
Depth net [mm]
565
605
760
870
Wall clearance back [mm]
160
160
160
160
Wall clearance sidewise [mm]
100
100
100
100
Environment-specific data
Energy consumption at 37 °C [Wh/h]
55
60
65
130
Sound-pressure level [dB(A)]
43
43
43
43
Fixtures
Number of shelves (std./max.)
2/4
2/5
2/8
2/16
Performance Data Temperature
Temperature range [°C] above ambient temperature
7
8
7
10
Temperature range to [°C]
100
100
100
100
Temperature variation at 37 °C [± K]
0.2
0.3
0.2
0.3
Temperature fluctuation at 37 °C [± K]
0.1
0.1
0.1
0.1
Heating-up time to 37 °C [min]
6
8
7
15
Recovery time after 30 seconds door open at 37 °C [min]
3
3
3
4
Electrical data
Rated Voltage [V]
230
230
230
230
Power frequency [Hz]
50/60
50/60
50/60
50/60
Nominal power [kW]
0.4
0.4
1
2
Unit fuse [A]
6.3
6.3
8
(16)
Phase (Nominal voltage) [ph]
1~
1~
1~
1~
All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
Downloads
Описание модели BF 56
Инкубаторы Binder Avantgarde.Line Серии BF Модель 56
Описание модели BF 115
Инкубаторы Binder Avantgarde.Line Серии BF Модель 115
Описание модели BF 260
Инкубаторы Binder Avantgarde.Line Серии BF Модель 260
Описание модели BF 720
Инкубаторы Binder Avantgarde.Line Серии BF Модель 720
To get information about: «Avantgarde.Line | BF Series Forced convection» contact us by phone (044) 229 15 31 or fill in the form.
E-mail
Phone
First name
Family name
Country
Company name
Request
Topic: Life Sciences Instruments, Incubators, Incubators Avantgarde.Line company BINDER GmbH. Text: Contact me.
Input symbols from the picture
Change the picture
You can also find free movies to stream online on
sflix
.